Ulster University Logo

Ulster Institutional Repository

Investigation of the effect of simulated lens yellowing, transparency loss and refractive error on in vivo resonance Raman spectroscopy

Biomedical Sciences Research Institute Computer Science Research Institute Environmental Sciences Research Institute Nanotechnology & Advanced Materials Research Institute

Hogg, R. E., Zlatkova, Margarita, Chakravarthy, U. and Anderson, Roger (2007) Investigation of the effect of simulated lens yellowing, transparency loss and refractive error on in vivo resonance Raman spectroscopy. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 27 (3). pp. 225-231. [Journal article]

Full text not available from this repository.

DOI: 10.1111/j.1475-1313.2006.00478.x

Abstract

Purpose: To separately investigate the impact of simulated age-related lens yellowing, transparency loss and refractive error on measurements of macular pigment (MP) using resonance Raman spectroscopy. Methods: Two healthy young subjects with clear media underwent Raman spectroscopy under the following conditions: age-related lens yellowing was simulated using seven broad-band yellow filters with transmittance at 488 nm ranging from 0.54 to 0.90; cataract was simulated using five white filters of increasing opacity (scatter filters), the transmittance of which ranged from 0.42 to 0.86, each of which reduced peak contrast sensitivity by approximately 0.1 log units over the previous filter. Refractive error up to +6.25 D was achieved using soft contact lenses. Results: The Raman signal declined steadily to an average value of 43% of the starting value with the densest yellow filter in place. The white scatter filters produced a progressive linear reduction in signal resulting in almost complete signal loss with the densest filter. Refractive error resulted in an initial slight improvement in Raman count up to a value of +2.00 D followed by a decline thereafter. Conclusions: These results imply that lens yellowing and increasing scatter has an influence on the Raman signal and suggest that studies using this technology to estimate MP levels in older populations should carefully account for the status of the lens.

Item Type:Journal article
Faculties and Schools:Faculty of Life and Health Sciences
Faculty of Life and Health Sciences > School of Biomedical Sciences
Research Institutes and Groups:Biomedical Sciences Research Institute
Biomedical Sciences Research Institute > Vision
ID Code:3928
Deposited By:Dr Margarita Vidinova
Deposited On:09 Feb 2010 11:57
Last Modified:04 Aug 2011 09:51

Repository Staff Only: item control page