Ulster University Logo

Ulster Institutional Repository

Do mattresses differ? A question at the nurse-engineer interface

Biomedical Sciences Research Institute Computer Science Research Institute Environmental Sciences Research Institute Nanotechnology & Advanced Materials Research Institute

Kernohan, George (1999) Do mattresses differ? A question at the nurse-engineer interface. Irish Journal of Medical Science, 168 (3). p. 212. [Journal article]

Full text not available from this repository.

URL: http://www.springerlink.com/

DOI: 10.1007/BF02945855

Abstract

A common clinical strategy for relief of pressure sores is theuse of pressure redistributing beds, mattresses and overlays. Alarge-scale mattress replacement was scheduled for 1998 andthis led to a multi-professional review of the pressure-relievingproperties of a range of foam mattresses. Mattresses weresubjected to 48 h indentor testing. Attention was paid to theabsolute peak pressures and the percentage change relative tothe initial readings. Having achieved a high ranking in indentortesting, selected mattresses were placed in the clinical settingfor a one-week period. A purchasing decision was made basedupon indentor testing, clinical evaluation and by examining price.For confirmation, a number of other major users were consulted.The 13 mattresses provided variable pressure relievingproperties. A process of exclusion was adopted in order to finda subset suitable for clinical evaluation. The standard NHSmattress performed poorly. One type was dual-function wherebythe mattress was intended to be matched for patient weight,having a "heavy" and a "light" side (deemed to be impractical).Some generated high initial pressures and were removed. Wediscarded mattresses that produced an increase in pressure overthe 24 h loading or that responded poorly after the rest period.The remaining mattresses were deemed suitable, on an equalbasis, for further testing. Three mattresses were placed on clinicaltrial for a one-week period, all performing satisfactorily. Pricewas examined in the context of manufacturers' guarantee usedas an indication of mattress life. On the basis of these findings,the team of nurses and engineers were able to make a purchasingrecommendation. We are confident that this will lead to fewerpressure sores, improved care and better patient outcome.

Item Type:Journal article
Faculties and Schools:Faculty of Life and Health Sciences
Faculty of Life and Health Sciences > School of Nursing
Research Institutes and Groups:Institute of Nursing and Health Research
Institute of Nursing and Health Research > Managing Chronic Illness
ID Code:17556
Deposited By:Professor George Kernohan
Deposited On:30 Mar 2011 16:07
Last Modified:23 Jul 2012 14:52

Repository Staff Only: item control page