Test–retest reliability of step counts with the ActivPALTM device in common daily activities

Biomedical Sciences Research Institute Computer Science Research Institute Environmental Sciences Research Institute Nanotechnology & Advanced Materials Research Institute

Dahlgren, Gunilla, Carlsson, Daniel, Moorhead, Anne, Häger-Ross, Charlotte and McDonough, Suzanne M (2010) Test–retest reliability of step counts with the ActivPALTM device in common daily activities. Gait & Posture, 32 (3). pp. 386-390. [Journal article]

[img]PDF (Journal Article) - Published Version
Restricted to Repository staff only

241Kb

DOI: 10.1016/j.gaitpost.2010.06.022

Abstract

The ActivPAL device is a well-established physical activity monitor for assessment of physical activity. Aim: To investigate test–retest reliability of step counts and establish minimal detectable changes (MDC) in step count to account for intra device error over time in various physical activities. Methods: Healthy participants (n = 24, age range, 19–28 years) performed activities on two occasions, 1 week apart, in a laboratory setting; self-paced floor walking, treadmill walking at three different speeds (3.2 km/h,4.5 km/h and 4.5 km/h with incline), treadmill jogging (8.0 km/h), stair walking and cycling on an exercise bike at three speeds (45 rpm, 60 rpm and 75 rpm). Relative reliability was calculated using intraclass correlation coefficient (ICC) and Spearman correlation. Absolute reliability was assessed using standard error of measurement (SEM) and coefficient of repeatability (CR). Results: The ActivPAL showed high to very high relative reliability for treadmill walking at all speeds and stair walking, while self-paced normal floor walking showed moderate reliability. The absolute reliability was the best for treadmill walking activities, slightly increased for self-paced walking, followed by stair walking and jogging. The use of activity monitors during cycling has been questioned and our results confirm a low absolute and relative reliability. MDC values varied according to the type of activity e.g. treadmill walking 4.5 km/h (10steps), walking on the floor (45 steps). Data loss in this study (10–13%) was higher than previously reported. Conclusions: The ActivPAL is reliable for treadmill walking, jogging and self-paced walking. MCD varies according to the activity and should be considered when establishing true change over time.

Item Type:Journal article
Keywords:Accelerometer Physical activity Reliability ActivPAL
Faculties and Schools:Faculty of Life and Health Sciences
Faculty of Social Sciences
Faculty of Life and Health Sciences > School of Health Sciences
Faculty of Social Sciences > School of Communication
Research Institutes and Groups:Institute for Research in Social Sciences
Institute of Nursing and Health Research > Centre for Health and Rehabilitation Technologies
Institute for Research in Social Sciences > Communication
ID Code:17212
Deposited By:Dr Anne Moorhead
Deposited On:21 Feb 2011 15:46
Last Modified:07 Apr 2014 11:20